A. The diverter plate cavity plate is higher than the diverter plate gasket, and the diverter plate cavity plate is reprocessed
B. Measure whether the opening of the nozzle cap is within the tolerance range on different surfaces of the nozzle cap
C. If there is any error in the height of the central gasket, locating
pin and anti rotation pin, check whether the depth of the central
locating hole and anti rotation pin hole meets the design requirements
and re process
D. The shunt plate plug leaks glue, and the plug is reprocessed
E. Check whether the fitting surface of the main nozzle is assembled in place
F. The processing of the sealing surface is not in place,
causing glue leakage. Check whether the size of the sealing surface is
within the tolerance range
G. The formwork of the mold is deformed, resulting in glue leakage.
Check whether the thickness, material and hardness of the formwork meet
the requirements
H. The shunt plate is deformed, resulting in glue leakage,
insufficient thickness of the shunt plate, or unreasonable setting of
the cushion block
1. The nozzle head is not tightened or cracked, tighten the nozzle head or reprocess the nozzle head
J. The guide shuttle is deformed or cracked. Check the size of the guide shuttle and replace the guide shuttle
K. The fitting gap between the flange and the main nozzle is too
large. Rework the flange to ensure that it meets the design requirements
50. If the opening of the mold does not meet the requirements
of the drawing, re process the mold to ensure that the opening meets
the requirements of the drawing